Introduction

If the water is not dispensing from your Hoover Power Path Deluxe FH50951, use this guide to replace the water dispenser.

The water dispenser dispenses water from the clean water tank to clean the carpet. If no water is dispensing, then the carpet will not be properly cleaned.

Replacing the water dispenser requires you to take out the brush rolls and the belt as well.

Before beginning, ensure your device is unplugged from a power source.

  1. TSR3RoEcEODPd6Ps
    TSR3RoEcEODPd6Ps
    DlDejFjPVMcOLDlL
    DtGxOm5r614tLFhA
    • Remove the four 18.6 mm screws labeled 1-4 using a Phillips #1 screwdriver.

    • Remove the piece that was being held down by those screws.

  2. WHqkAU5CGOuEFmkl
    WHqkAU5CGOuEFmkl
    POVgdqEMdPSn1RVx
    VxEEIdBKERq6JHcX
    • Remove the four 18.6 mm screws with arrows listing 5-8 using a Phillips #1 screwdriver.

    • Remove the wheel assembly on the left side of the vacuum.

    • You may need a longer Phillips #1 screwdriver for screw #7.

  3. iRNkrwELyTCkIMGR
    • Lift up the belt to give enough slack to allow the brush roll to come out.

    • While lifting the belt, pull/push upward away from the cleaner to pop it out.

    • It may seem like the brush rolls wont come out but just put more force into it.

  4. 3IcwCZR1rbAnh6p6
    3IcwCZR1rbAnh6p6
    QbHIlmlEuUPkehTD
    • Gently slide the belt off of the motor shaft and lift it out of the vacuum.

    • Loop one end of the new belt around the motor shaft, making sure it sits securely in the groove.

    • Ensure the belt is securely placed in the correct slot on both the motor shaft and the brush roll. A loosely installed or improperly positioned belt can slip, break, or prevent the brush roll from spinning correctly, potentially damaging your vacuum. Double-check that the belt is aligned and tensioned properly before reassembling the vacuum.

  5. ayUDGYPPJIfNXXSs
    ayUDGYPPJIfNXXSs
    XESNqHHgHPZYeEfC
    • Remove the four 18.6 mm screws using a Phillips #1 screwdriver.

    • Remove the wheel assembly on the right side of the vacuum.

  6. nVxGZD4LkZkjSGwL
    nVxGZD4LkZkjSGwL
    sv1vwhLINGLsBXtQ
    kPP1uscAnooHPALJ
    • Remove the two 12.6 mm screws using a Phillips #1 screwdriver.

    • Remove the piece.

  7. KqlCBKjkcJKBbUPF
    • Hold the dispenser in one hand and the tube that is attached to the bottom in the other hand and pull.

    • It should just pull straight off, no twisting.

Conclusion

To reassemble your device, follow these instructions in reverse order.