Introduction
The Work Piece Contact Assembly is critical to proper function of the nail gun and is composed of several parts that each can fail and require the entire assembly to be disassembled and replace to restore proper function.
Make sure to have a 5/32" Allen wrench.
Tools
-
-
Remove the single 25 mm hex screw that secures the workpiece contact cover with a 5/32" Allen wrench.
-
Remove the single 14 mm hex screw that secures the magazine to the lower handle with a 5/32" Allen wrench
-
-
-
Release the depth adjustment knob by rotating it counterclockwise.
-
Remove the workpiece contact by pulling it parallel to the device.
-
Conclusion
To reassemble your device, follow these instructions in reverse order.